Try five free New Hampshire electrician practice questions with answers and 2020 NEC references. They follow the content areas Prov lists for the Journeyman Electrician 2020 and Master Electrician 2020 exams, where motors and generators alone carry 19 questions. Answer all five with your code book open, then check the explanations.
New to the exam? Read the New Hampshire electrician exam guide for the format, allowed books and remote testing rules.
Booked for the 2020 journeyman or master exam? JCR's New Hampshire package is built on the 2020 NEC. $495 gets you 100 video lessons running 21 hours, a 152-page workbook, 500+ mock exam questions in print and online, and permanent code tabs.
Rather learn live? JCR's live Zoom exam prep class teaches the 2020 NEC in four 4-hour sessions on Tuesday evenings and Saturday mornings, Eastern time. The $800 class includes the videos, workbook and mock exam.
New Hampshire exam facts at a glance
| Quick facts | New Hampshire electrician exams |
|---|---|
| Test company | Prov, under its New Hampshire bulletin revised November 9, 2026 |
| Journeyman Electrician 2020 | 110 questions, 4.5 hours, 70% to pass, $90 |
| Master Electrician 2020 | 126 questions, 5 hours, 70% to pass, $90 |
| Books | Open book. The 2020 NEC, Ugly's Electrical References and the other titles on Prov's list. |
New Hampshire electrician practice test: 5 questions
Allow 12 minutes. That matches the exam's pace of about 2.4 minutes a question. Treat this as a lookup drill, not a forecast of your score.
Question 1: Motors
A motor circuit rated under 1000 volts supplies a motor with a full-load current of 28 amps. What is the smallest ampere rating allowed for its disconnecting means?
- 28 amps
- 32.2 amps
- 35 amps
- 42 amps
Question 2: Generators
A generator nameplate shows 100 amps. What is the minimum ampacity of the conductors from the generator terminals to the first distribution device with overcurrent protection?
- 100 amps
- 115 amps
- 125 amps
- 150 amps
Question 3: Control devices
A switch is mounted on a wall. With its operating handle in the highest position, how high above the floor can the center of the handle grip be?
- 5 feet
- 6 feet
- 6 feet 7 inches
- 7 feet
Question 4: Services
Overhead service conductors attach to a house. What is the lowest height allowed for the point of attachment above finished grade?
- 8 feet
- 10 feet
- 12 feet
- 15 feet
Question 5: Feeders
A feeder is protected by a 400-amp breaker. Tap conductors 20 feet long are installed under the 25-foot tap rule. What is their minimum ampacity?
- 40 amps
- 100 amps
- 133.3 amps
- 200 amps
Answer key with NEC sections
Score one point for each right answer. Then read every section you missed in your own 2020 NEC.
Show the answer to question 1Hide the answer to question 1
1. B, 32.2 amps (NEC 430.110(A))
Section 430.110(A) requires the disconnecting means for a motor circuit rated 1000 volts or less to have an ampere rating of at least 115% of the motor's full-load current. 28 × 1.15 = 32.2 amps. The 125% figure in choice C is for motor conductors, not the disconnect.
Show the answer to question 2Hide the answer to question 2
2. B, 115 amps (NEC 445.13(A))
Section 445.13(A) sets the conductor ampacity at 115% of the generator's nameplate current rating or more. 100 × 1.15 = 115 amps. An exception allows 100% where the generator's design and operation prevent overloading.
Show the answer to question 3Hide the answer to question 3
3. C, 6 feet 7 inches (NEC 404.8(A))
Section 404.8(A) requires switches, and circuit breakers used as switches, to be readily accessible. The center of the handle grip, in its highest position, can be no more than 6 feet 7 inches above the floor or working platform. The section lists three exceptions.
Show the answer to question 4Hide the answer to question 4
4. B, 10 feet (NEC 230.26)
Section 230.26 says the point of attachment can never be less than 10 feet above finished grade. It must also be high enough to give the clearances in 230.9 and 230.24.
Show the answer to question 5Hide the answer to question 5
5. C, 133.3 amps (NEC 240.21(B)(2))
Under the 25-foot rule in 240.21(B)(2), the tap conductors need an ampacity of at least one-third of the rating of the device protecting the feeder. 400 ÷ 3 = 133.3 amps. The taps must also end in a single breaker or set of fuses and be protected from physical damage. One-tenth, or 40 amps, belongs to the 10-foot rule in 240.21(B)(1).
How to use your score
- Missed question 1 or 2? Motors and generators are 19 questions on both 2020 exams. Work through Article 430 Parts II, III, IV and IX.
- Slow on question 5? Tab 240.21 and learn the 10-foot and 25-foot rules side by side.
- Write out each percentage. 115%, 125% and one-third are easy to swap under time pressure.
- Keep these questions out of your books. Prov bans handwritten notes and anything added to a reference.
New Hampshire electrician practice test FAQ
Are these official New Hampshire exam questions?
No. They are JCR NEC mock exam questions for practice. Prov and the Electricians' Board do not supply or endorse them.
Which NEC edition do these questions use?
The 2020 NEC, the edition tested on Prov's Journeyman Electrician 2020 and Master Electrician 2020 exams.
Does this practice test cover the administrative questions?
No. The journeyman exam has 9 administrative questions and the master exam has 25. They come from RSA 319-C and the Board's rules.
Keep practicing for your New Hampshire exam
See the full New Hampshire electrician exam guide for books, fees and scheduling.
Sources and answer references
- Prov: New Hampshire Electrician Board Candidate Information Bulletin (version 1.1, revised November 9, 2026)
- OPLC: Electricians' Board
- NFPA 70, 2020 NEC (free access): 230.26, 240.21(B)(1) and (B)(2), 404.8(A), 430.110(A) and 445.13(A)
JCR checked each answer against the 2020 NEC and the exam facts against Prov's New Hampshire bulletin on November 13, 2026.